Compare
All categories
All categories

TCF-142-S-ST-RM

Serial converter, Serial: RS-232, RS-422, RS-485, Temp: 0 to 60°C (32 to 140°F)

Your price without VAT494 EUR
Not in stock (0 pcs)
Unit:pcs
Code 1:182020024070
Warranty:60
Warranty for companies: 60
Brand:MOXA

Description

Serial converter – RS-232/422/485 to single-mode fiber slide-in module converter, ST connector

Serial Interface

  • No. of Ports: 2
  • Serial Standards: RS-232, RS-422, RS-485
  • Baudrate: 50 bps to 921.6 kbps (supports non-standard baudrates)
  • Flow Control: ADDC® (automatic data direction control) for RS-485
  • Connector: Single-mode ST connector
  • Optical Fiber: Read more Low-Speed Fiber Module Multi-Mode Single-Mode Fiber Cable Requirements 50/125 µm, 800 MHz G.652 62.5/125 µm, 500 MHz Typical Distance 5 km 40 km Wavelength Typical (nm) 850 1310 TX Range (nm) 840 to 860 1290 to 1330 RX Range (nm) 800 to 900 1100 to 1650 Optical Power TX Range (dBm) 0 to -5 0 to -5 RX Range (dBm) 0 to -20 0 to -25 Link Budget (dB) 15 20 Dispersion Penalty (dB) 1 1 Note: When using a power meter to measure the fiber TX power, set the baudrate to 9,600 bps and send data (00, ..., 0h) to the serial converter’s serial port.
  • Pull High/Low Resistor for RS-485: 1 kilo-ohm, 150 kilo-ohms
  • RS-485 Data Direction Control: ADDC® (automatic data direction control)
  • Terminator for RS-485: N/A, 120 ohms, 120 kilo-ohms

Serial Signals

  • RS-232: TxD, RxD, GND
  • RS-422: Tx+, Tx-, Rx+, Rx-, GND
  • RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
  • RS-485-2w: Data+, Data-, GND

Power Parameters

  • Input Current: 150 mA @ 12 VDC
  • Overload Current Protection: Supported
  • Power Consumption: 150 mA @ 12 VDC

Physical Characteristics

  • Housing: Metal
  • IP Rating: IP30
  • Dimensions: 86.8 x 136.5 x 21 mm (3.42 x 5.37 x 0.83 in)
  • Weight: 105 g (0.23 lb)

Environmental Limits

  • Operating Temperature: 0 to 60°C (32 to 140°F)
  • Storage Temperature (package included): -20 to 75°C (-4 to 167°F)
  • Ambient Relative Humidity: 5 to 95% (non-condensing)

Standards and Certifications

  • EMC: EN 55032/24
  • EMI: CISPR 32, FCC Part 15B Class A
  • EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 2 kV(AC), 1 kV(DC) IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF
  • Environmental Testing: IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-3
  • Safety: EN 60950-1, IEC 60950-1
  • Vibration: IEC 60068-2-6

MTBF

  • Time: 514,926 hrs
  • Standards: Telcordia (Bellcore), GB

Warranty

Technical specification

Ratings

You have already rated the product

Zboží bylo vloženo do hromadné poptávky

{common::4::askForPriceAddError}

Price inquiry

{common::5::askForPriceFormText}

Acceptance with the processing of personal data is mandatory.

Poptávku na cenu se nepodařilo odeslat
Poptávka na cenu byla odeslaná
Login to the newsletter was successful.
Something is wrong, contact us.

Košík obsahuje nepovolené položky

Košík je prázdný

Show basket

The article was added to comparison

Please wait...
Unable to complete your order, please try again later